01 March 2018 : Case report
Intracardiac Abscess and Pacemaker Lead Infection Secondary to Hematogenous Dissemination of Methicillin-Sensitive Staphylococcus Aureus from a Prior Diabetic Foot Ulcer and Osteomyelitis
Rare disease
Kristopher S. Pfirman1ABCDEF*, Robel Haile2ACDDOI: 10.12659/AJCR.906227
Am J Case Rep 2018; 19:224-228
Abstract
BACKGROUND: Intracardiac abscesses are an unusual occurrence in developed countries. With the increase in use of implantable cardiac devices, the increase use of and advancements in antibiotics, and the longevity of patients with cardiac devices, one may expect an increase in such infections; however, case reports are rare. We are presenting a case in which hematogenous dissemination of methicillin-sensitive Staphylococcus aureus (MSSA) infection from a lower extremity diabetic ulcer propagated into an infected pacemaker lead and ultimately an intracardiac abscess of the right atrium.
CASE REPORT: A 77-year-old male with a history of MSSA diabetic foot infection complicated by osteomyelitis presented with fever, syncope, and wide complex tachycardia, and he was found to have an intracardiac abscess and fibrinous lead vegetations. The patient was deemed too ill for invasive surgical intervention given his comorbidities, pacemaker generator replacement requirement, and intermittent ventricular tachycardia. The patient was subsequently sent home with oral antibiotics and home hospice per patient and family wishes.
CONCLUSIONS: This case demonstrated how hematogenous dissemination of MSSA infections from a diabetic foot ulcer and osteomyelitis can seed pacemaker hardware resulting in an intracardiac abscess. Unfortunately, our patient was too ill to undergo all procedures required to eradicate the abscess and infected pacemaker hardware. The standard of care would be complete hardware removal. Conservative management would include indefinite or prolonged antibiotic therapy, with the notion that intracardiac abscesses cannot be cured with antibiotics alone. This conservative management approach would be deemed necessary in a select population that cannot undergo surgical intervention.
Keywords: Abscess, Endocarditis, Bacterial, Pacemaker, Artificial, Staphylococcus aureus
In Press
16 Mar 2024 : Case report
A Rare Autochthonous Case of Hepatic Hydatid Cyst in the Non-Endemic Region of TaiwanAm J Case Rep In Press; DOI: 10.12659/AJCR.943687
17 Mar 2024 : Case report
Contrast-Enhanced Ultrasonography in Diagnosing Intravascular Large B-Cell Lymphoma Infiltrating Liver Sinu...Am J Case Rep In Press; DOI: 10.12659/AJCR.943070
17 Mar 2024 : Case report
Rare Presentation of Rapidly Involuting Congenital Hemangioma of the Skull: A Case ReportAm J Case Rep In Press; DOI: 10.12659/AJCR.943370
18 Mar 2024 : Case report
Perineal Benign Symmetric Lipomatosis in a Female Patient: A Case ReportAm J Case Rep In Press; DOI: 10.12659/AJCR.943803
Most Viewed Current Articles
07 Mar 2024 : Case report
Neurocysticercosis Presenting as Migraine in the United StatesDOI :10.12659/AJCR.943133
Am J Case Rep 2024; 25:e943133
10 Jan 2022 : Case report
A Report on the First 7 Sequential Patients Treated Within the C-Reactive Protein Apheresis in COVID (CACOV...DOI :10.12659/AJCR.935263
Am J Case Rep 2022; 23:e935263
19 Jul 2022 : Case report
Atlantoaxial Subluxation Secondary to SARS-CoV-2 Infection: A Rare Orthopedic Complication from COVID-19DOI :10.12659/AJCR.936128
Am J Case Rep 2022; 23:e936128
23 Feb 2022 : Case report
Penile Necrosis Associated with Local Intravenous Injection of CocaineDOI :10.12659/AJCR.935250
Am J Case Rep 2022; 23:e935250