Fetal and Maternal Responses to Dexmedetomidine Intrathecal Application During Cesarean Section: A Meta-Analysis

ShuJun Sun, JiaMei Wang, JingXu Wang, FuQuan Wang, HaiFa Xia, ShangLong Yao

(Department of Anesthesiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China (mainland))

Med Sci Monit 2020; 26:e918523

DOI: 10.12659/MSM.918523


BACKGROUND: Intrathecal dexmedetomidine (DEX) can improve the blockade of spinal anesthesia, but there is no clear conclusion on whether it has an effect on the fetus during cesarean section. Our meta-analysis evaluated the safety and efficacy of intrathecal DEX in cesarean delivery.
MATERIAL AND METHODS: We searched Cochrane, Embase, PubMed, and CBM for eligible studies, and used the Revised Cochrane Risk of Bias Tool (RoB 2.0) to assess the risk of bias of each study. RevMan was used for statistical analyses. We have registered this meta-analysis on PROSPERO (CRD42019120995).
RESULTS: The meta-analysis included 10 RCTs, but only 5 were prospectively registered. The results of preregistration studies, including the 1- or 5-min Apgar score (mean difference [MD], -0.03; 95% confidence intervals [CI], -0.16 to 0.10; P=0.64 or MD, 0.00; 95% CI, -0.09 to 0.09; P=1), the umbilical arterial oxygen or carbon dioxide partial pressure (MD, 0.90; 95% CI, -4.92 to 6.72; P=0.76 or MD, 1.20; 95% CI, -2.06 to 4.46; P=0.47), and the cord blood pH (MD, -0.01; 95% CI, -0.05 to 0.03; P=0.72), showed that intrathecal DEX had no significant difference in neonatal outcomes compared with placebo. In maternal outcomes, intrathecal DEX significantly prolonged postoperative pain-free period and reduced the incidence of postoperative shivering, which did not increase spinal anesthesia-associated adverse effects.
CONCLUSIONS: Intrathecal DEX is safe for the fetus during cesarean section and can improve the blockade effects of spinal anesthesia on puerperae.

This paper has been published under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially.