Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

31 March 2018 : Clinical Research  

Ventricular diastolic dimension over maximal myocardial thickness is robust landmark of systolic impairment in patients with hypertrophic cardiomyopathy

Marko Boban12ABDE*, Vladimir Pesa1B, Helena Antic Kauzlaric1D, Sandro Brusich3E, Ante Rotim1B, Tomislav Madzar2EF, Marinko Zulj4BC, Aleksandar Vcev2EF

DOI: 10.12659/MSM.906111

Med Sci Monit 2018; 24: CLR1880-1886

Abstract

BACKGROUND: The effects of focal hypertrophy on geometry of the left ventricle and systolic function have not been studied in patients with hypertrophic cardiomyopathy (HCM), despite the fact that the former is the most prominent disease characteristic. The aim of our study was to analyze systolic function over ventricle geometry, generating a functional index made from left ventricle end diastolic dimension (LVEDD) divided by end diastolic thickness of the region with maximal extent of hypertrophy and interventricular septum.

MATERIAL AND METHODS: Our hospital database of cardiac magnetic resonance was screened for HCM. Geometric functional index (GFI) was calculated for LVEDD over maximal end diastolic thickness (MaxEDT) giving GFI-M, while LVEDD over interventricular septum was expressed as GFI-I. There were 55 consecutive patients with HCM.

RESULTS: There were 43 males (78.2%) and 12 females (21.8%). The mean age was 52.3±16.7 years (range: 15.5–76.4 years). A significant difference of GFI was found for preserved versus impaired systolic function of the left ventricle (preserved systolic function); GFI-M 2.28±0.60 versus 3.66±0.50 (p<0.001), and GFI-I 2.75±0.88 versus 3.81±0.87 (p<0.001), respectively. Diagnostic value was tested using receiver operating curve (ROC) analyzes, with GFI-M area under curve (AUC)=0.959 (95% CI: 0.868–0.994); (p<0.001) and GFI-I-AUC=0.847 (0.724–0.930); (p<0.001). GFI-M was superior to GFI-I for appraisal of left ventricle systolic dysfunction in HCM; ΔAUC=0.112 (0.018–0.207); (p=0.020).

CONCLUSIONS: GFI is a simple tool, with high sensitivity and specificity for detecting impairment of systolic function in patients with HCM. Further studies would be necessary to investigate its clinical and prognostic impacts, as well as reproducibility with prospective validation.

Keywords: Cardiomyopathy, Hypertrophic, Heart Ventricles, Magnetic Resonance Imaging, Cine

Add Comment 0 Comments

Editorial

01 July 2026 : Editorial  

Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development Accelerates

Dinah V. Parums ORCID logo

DOI: 10.12659/MSM.954627

Med Sci Monit 2026; 32:e954627

0:00

In Press

Clinical Research  

Association Between Total Cholesterol–to–High-Density Lipoprotein Ratio and Gestational Hypertension: A Cas...

Med Sci Monit In Press; DOI: 10.12659/MSM.952395  

Review article  

Clinical Use of Endotracheal Intubation Without Neuromuscular Blockade: The Current Stage of Knowledge

Med Sci Monit In Press; DOI: 10.12659/MSM.951765  

Clinical Research  

Effect of Dexmedetomidine Hydrochloride Nasal Spray on Anxiety and Sleep in Patients Undergoing Gynecologic...

Med Sci Monit In Press; DOI: 10.12659/MSM.952465  

Clinical Research  

Prognostic Value of Mortality Scoring Systems in Patients With Severe Burns: Identifying Key Predictors of ...

Med Sci Monit In Press; DOI: 10.12659/MSM.951713  

Most Viewed Current Articles

17 Jan 2024 : Review article   14,176,173

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

13 Nov 2021 : Clinical Research   3,757,769

Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...

DOI :10.12659/MSM.932788

Med Sci Monit 2021; 27:e932788

0:00

14 Dec 2022 : Clinical Research   2,466,143

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research   708,797

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750