20 October 2017 : Clinical Research
Low kV and Low Concentration Contrast Agent with Iterative Reconstruction of Computed Tomography (CT) Coronary Angiography: A Preliminary Study
Hong Zhang1ADG*, Yanhe Ma1BCD, Jun Lyu1BCD, Yapeng Yang1BCD, Wei Yuan1BCD, Zhenchun Song1BCDDOI: 10.12659/MSM.904251
Med Sci Monit 2017; 23:5005-5010
Abstract
BACKGROUND: The aim of this study was to evaluate the image quality and radiation dose of CT coronary angiography (CTCA) with low kV, low concentration contrast agent, and iterative reconstruction.
MATERIAL AND METHODS: Ninety cases were randomly divided into 3 groups according to contrast agent concentration: group A 270 mg/ml (100 kV), group B 350 mg/ml (120 kV), and group C 370 mg/ml (120 kV), with 30 cases per group. Tube current was 200–250 mAs. Collimator width was 128×0.6 mm. Rotation speed was 0.27 s. The CT value of the left and right coronary arteries and the ascending aortic root was measured. The SNR and CNR of the images were calculated to evaluate the image quality objectively. The CTDI, DLP, and contrast injection were recorded.
RESULTS: There were no significant differences in sex, age, weight, height, and BMI among the 3 groups. There was no statistically significant difference between left and right coronary artery and ascending aortic root CT value, background noise, SNR, and CNR. Compared to B and C, the ED in group A decreased by about 27.58% and 28.21%, respectively. The total amount of iodine in group A was decreased by about 21.27% and 24.83%, respectively compared with groups B and C.
CONCLUSIONS: Low kV and low concentration contrast agent combined with iterative reconstruction for CTCA imaging produced image quality consistent with that of conventional CTCA and significantly reduced the dosage of the radiation and injected iodine.
Keywords: Cardiovascular Agents, Radiology Department, Hospital, Tomography Scanners, X-Ray Computed
Editorial
01 July 2026 : Editorial
Editorial: The WHO Identifies Ebola Disease Due to Bundibugyo Virus as a Public Health Emergency of International Concern (PHEIC) as Vaccine Development AcceleratesDOI: 10.12659/MSM.954627
Med Sci Monit 2026; 32:e954627
In Press
Review article
Clinical Use of Endotracheal Intubation Without Neuromuscular Blockade: The Current Stage of KnowledgeMed Sci Monit In Press; DOI: 10.12659/MSM.951765
Clinical Research
Effect of Dexmedetomidine Hydrochloride Nasal Spray on Anxiety and Sleep in Patients Undergoing Gynecologic...Med Sci Monit In Press; DOI: 10.12659/MSM.952465
Clinical Research
Prognostic Value of Mortality Scoring Systems in Patients With Severe Burns: Identifying Key Predictors of ...Med Sci Monit In Press; DOI: 10.12659/MSM.951713
Laboratory Research
Evaluation of the Trueness and Precision of Cast, Milled-Cast, Milled, and 3D-Printed Post-and-Core Techniq...Med Sci Monit In Press; DOI: 10.12659/MSM.953491
Most Viewed Current Articles
17 Jan 2024 : Review article 14,176,214
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
13 Nov 2021 : Clinical Research 3,757,839
Acceptance of COVID-19 Vaccination and Its Associated Factors Among Cancer Patients Attending the Oncology ...DOI :10.12659/MSM.932788
Med Sci Monit 2021; 27:e932788
14 Dec 2022 : Clinical Research 2,466,153
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research 708,809
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387