Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

29 February 2016 : Clinical Research  

Comparison of Clinical Efficacy Between Modular Cementless Stem Prostheses and Coated Cementless Long-Stem Prostheses on Bone Defect in Hip Revision Arthroplasty

Huibin LiABCEF, Fang ChenBCDE, Zhe WangBCD, Qian ChenDEF

DOI: 10.12659/MSM.895709

Med Sci Monit 2016; 22:670-677

Abstract

BACKGROUND: The aim of this study was to investigate and compare the clinical efficacy of modular cementless stem and coated cementless long-stem prostheses in hip revision arthroplasty.

MATERIAL AND METHODS: Sixty-five patients with complete hip revision surgery data during January 2005 to March 2015 were selected from the People’s Hospital of Linyi City and randomly divided into a S-ROM group (implanted with cementless modular stem prostheses, n=32) and a SLR-PLUS group (implanted with cementless coated long-stem prostheses, n=33). Harris score was used to evaluate the hip function of the patients in order to measure the clinical efficacy of the prostheses in total hip arthroplasty. Anteroposterior pelvic radiographs and lateral pelvic radiographs were taken and each patient’s hip arthroplasty condition was recorded. Kaplan-Meier method was applied to compare the cumulative 5-year non-revision rate between the 2 prostheses and log-rank method was used to inspect the statistical data.

RESULTS: The Harris scores of both the S-ROM group and the SLR-PLUS group were significantly higher at 12 months after the operation than those before the operation (both P<0.05). The Harris scores of the patients with type I/II bone defects in the S-ROM group were not significantly different from those of the same types in the SLR-PLUS group at all time points (all P>0.05), while the Harris scores of the patients with type IIIA/IIIB in the S-ROM group were both significantly higher than those of the same types in the SLR-PLUS group at 3 months, 6 months, and 12 months after the operation (all P<0.05). No significant difference was found in the cumulative 5-year non-revision rate between the type I/II patients in the S-ROM group (92.31%) and the patients of the same types in the SLR-PLUS group (85.71%) (P>0.05). However, the cumulative 5-year non-revision rate of the type IIIA/IIIB patients in the S-ROM group (89.47%) was significantly different from the patients of the same types in the SLR-PLUS group (42.11%) (P<0.05).

CONCLUSIONS: The modular stem prostheses in hip revision arthroplasty were clinically more effective in the treatment of type IIIA and IIIB bone defects than the coated long-stem prostheses according to the Harris score and the cumulative 5-year non-revision rate.

Keywords: Arthroplasty, Replacement, Hip, Bone Cements, Coated Materials, Biocompatible - pharmacology, Hip - pathology, Hip Prosthesis, Postoperative Care, Preoperative Care

Add Comment 0 Comments

Editorial

01 April 2024 : Editorial  

Editorial: Forty Years of Waiting for Prevention and Cure of HIV Infection – Ongoing Challenges and Hopes for Vaccine Development and Overcoming Antiretroviral Drug Resistance

Dinah V. Parums

DOI: 10.12659/MSM.944600

Med Sci Monit 2024; 30:e944600

0:00

In Press

06 Mar 2024 : Clinical Research  

Prevalence and Variation of Medical Comorbidities in Oral Surgery Patients: A Retrospective Study at Jazan ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943884  

08 Mar 2024 : Clinical Research  

Evaluation of Foot Structure in Preschool Children Based on Body Mass

Med Sci Monit In Press; DOI: 10.12659/MSM.943765  

15 Apr 2024 : Laboratory Research  

The Role of Copper-Induced M2 Macrophage Polarization in Protecting Cartilage Matrix in Osteoarthritis

Med Sci Monit In Press; DOI: 10.12659/MSM.943738  

07 Mar 2024 : Clinical Research  

Knowledge of and Attitudes Toward Clinical Trials: A Questionnaire-Based Study of 179 Male Third- and Fourt...

Med Sci Monit In Press; DOI: 10.12659/MSM.943468  

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750