Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

27 December 2021: Clinical Research

A Retrospective Single-Center Study of 23 Patients to Compare Gait Before and After Total Hip Arthroplasty Using the S-ROM Modular Hip System

Jaqueline Bahr 1BCDEF , Dietmar Rosental 2C , Tim Classen 3E , Sonja Krebs 4E , Marcus Jäger 1AG*

DOI: 10.12659/MSM.934558

Med Sci Monit 2021; 27:e934558

Table 6 Passive hip range of motion, leg length difference and Harris hip score.

NPreoperative*NPostoperative*p1
Leg length difference231.17 (0.87)# 230.94 (1.19)# 0.198
Passive hip extension238.39 (5.80)# 238.61 (3.09)# 0.787
Passive hip flexion2382.39 (25.40)# 2394.13 (15.86)#
Passive hip abduction2318.04 (7.03)# 2322.61 (7.21)#
Passive hip adduction2312.83 (6.37)# 2314.57 (5.82)# 0.336
Passive hip internal rotation2316.74 (12.02)# 2327.61 (11.27)#
Passive hip external rotation2316.30 (9.80)# 2323.04 (6.87)#
Pain (HHS)2112.38 (±8.31)2133.81 (±10.43)
Function (HHS)2112.81 (±3.98)2119.52 (±4.09)
ROM and deformity (HHS)217.29 (±1.06)218.57 (±2.52)
Gait pattern (HHS)2114.90 (±5.03)2117.29 (±4.80)
HHS-total2147.38 (±12.25)2179.19 (±15.75)
* The mean and simple standard deviation are given;
# values are given in angle degree.
p1: p-value for the test preoperative in comparison with postoperative (Wilcoxon Test).

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.