Table 2 Genotype and allele distributions of VDR gene 9 studied variants between cases and controls, and genotype-based risk prediction for sepsis mortality risk.

VariantsCases (n=267)Controls (n=283)p ValueOR, 95% CI, p value
rs9729CC133 (52%)144 (53%)0.98Reference group
AC104 (41%)112 (41%)1.05, 0.72–1.52, 0.81
AA18 (7%)18 (6%)1.13, 0.55–2.31, 0.74
A27%27%0.87
rs2107301TT154 (59%)135 (48%)0.01Reference group
TC95 (36%)121 (43%)0.70, 0.48–1.01, 0.06
CC12 (5%)26 (9%)0.44, 0.21–0.92, 0.03
C23%31%0.003
rs2189480AA137 (52%)109 (39%)0.004Reference group
CA106 (40%)137 (49%)0.62, 0.43–0.90, 0.01
CC19 (8%)35 (12%)0.43, 0.23–0.81, 0.009
C27%37%0.001
rs2239185CC135 (51%)154 (55%)0.32Reference group
CT108 (41%)115 (41%)1.11, 0.77–1.59, 0.59
TT20 (8%)13 (5%)1.94, 0.91–4.14, 0.09
T28%25%0.24
rs3782905CC192 (80%)195 (75%)0.20Reference group
CG48 (20%)60 (23%)0.83, 0.53–1.31, 0.43
GG1 (0.4%)5 (2%)0.26, 0.03–2.39, 0.23
G11%13%0.13
rs4516035TT249 (95%)267 (96%)0.41Reference group
CT14 (5%)10 (4%)1.62, 0.66–3.94, 0.29
CC0 (0%)1 (0.4%)Unavailable
C3%2%0.59
rs7139166CC248 (95%)271 (96%)0.54Reference group
CG14 (5%)11 (4%)1.52, 0.64–3.63, 0.35
GG0 (0%)1 (0.4%)Unavailable
G3%2%0.69
rs11168266GG135 (52%)149 (53%)0.72Reference group
GA104 (40%)105 (38%)1.15, 0.79–1.68, 0.45
AA20 (8%)26 (9%)0.89, 0.46–1.70, 0.72
A28%28%
rs11168293GG250 (96.53%)272 (96.80%)0.86Reference group
GT9 (3%)9 (3%)1.24, 0.46–3.35, 0.68
TT0 (0%)0 (0%)Unavailable
T3%3%0.93
OR – odds ratio; 95% CI – 95% confidence interval. The values were calculated after adjusting for age and sex in a logistic regression analysis.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.