Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

11 January 2021: Clinical Research

Lightwand-Guided Insertion of Flexible Reinforced Laryngeal Mask Airway: Comparison with Standard Digital Manipulation Insertion

Dae Hee Kim BCD* , Yun Jeong Chae ADE* , Sang Kee Min CD , Eun Ji Ha BC , Ji Young Yoo ABEFG*

DOI: 10.12659/MSM.928538

Med Sci Monit 2021; 27:e928538

Table 3 Oropharyngeal leak pressure, peak inspiratory pressure, and expiratory tidal volume in several positions.

VariableControl group (n=27)Lightwand group (n=27)P value
OLP (cmHO)0.478
 Neutral27.9±7.530.3±8.7
 Extension20.4±8.1* 20.5±9.7*
 Rotation30.4±6.229.5±8.1
 Flexion27.7±7.428.1±8.2
 Re-neutral27.9±6.331.2±7.7
PIP0.104
 Neutral18.5±4.417.3±2.7
 Extension16.3±3.7* 14.9±7.4
 Rotation17.9±3.317.1±2.6
 Flexion20.2±7.017.3±3.3
 Re-neutral19.1±5.217.6±3.2
Expiratory tidal volume0.521
 Neutral445.5±92.6454.8±142.6
 Extension302.7±141.5* 315.4±189.2*
 Rotation457.9±101.1480.9±117.8
 Flexion437.1±117.1449.9±126.6
 Re-neutral460.7±84.8477.5±101.6
Values are presented as median (interquartile range) or mean±SD or numbers. Control group – standard digital manipulation method group; Lightwand group – lightwand guided method group; OLP – oropharyngeal leak pressure; PIP – peak inspiratory pressure.
* Significant different compared to neutral position.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750