Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

07 October 2021: Clinical Research  

Use of a Percutaneous Needle Release Technique for Trigger Thumb: A Retrospective Study of 11 Patients from a Single Center

Xianjie Sun12ABCDEF, Haidong Wang3BDEF, Xingen Zhang12ABCDEFG*, Bangjian He4ABCDEF

DOI: 10.12659/MSM.931389

Med Sci Monit 2021; 27:e931389

0 Comments

Abstract

BACKGROUND: Trigger finger is a very common disorder that occurs in both adults and children. Trigger finger presents mainly as pain and limited movement of the affected digit. This report describes a modified percutaneous needle release and an evaluation of its clinical efficacy to treat trigger thumb.

MATERIAL AND METHODS: Trigger thumb of 11 patients was released percutaneously using a specially designed needle (0.8×100 mm) with a planus tip. Complete release was ensured when no more grating sound was heard and the needle moved freely at the tip. Pain-related functional score was evaluated preoperatively and at 3 months postoperatively. Resolution of Notta’s node, triggered or locked, Quinnell’s criteria, and patient satisfaction were also assessed at 3 months after the operation.

RESULTS: After the percutaneous trigger thumb release, the overall visual analog scale (VAS) and pain-related functional scores declined significantly (P<0.01). There was no recurrence of thumb locking or triggering or Notta’s node. Only the first patient had incomplete release of the first annular pulley, and all patients showed high satisfaction with the procedure at 3 months after their operation. During the study, patients did not experience any complications such as inflammation, edema, or digital nerve injury.

CONCLUSIONS: This study demonstrated that the percutaneous technique is effective, less time-consuming, and safe for treating trigger thumb. Our release technique using a specially designed percutaneous needle is a valuable treatment for trigger thumb.

Keywords: Actinoplanes digitatis, Biopsy, Fine-Needle, Trigger Finger Disorder, Follow-Up Studies, Humans, Minimally Invasive Surgical Procedures, Needles, Orthopedic Procedures, Pain, Pain Measurement, Patient Satisfaction, Recovery of Function

Background

Trigger finger is a very common disorder that occurs in both adults and children. It presents mainly with pain and limited movement of the affected digit [1]. The main triggering mechanism is on the first annular (A1) pulley, following long-term friction and compression leading to an obstruction of the flexor tendon gliding in the fibrous sheath. It generally involves the thumb [2].

Various conservative treatments have been confirmed effective to treat this bothersome condition [3–5], but not all cases can be resolved entirely. Overall, the success rate ranges from 35% to 80% with regard to resolution of patients’ pain and triggering [6–8]. Once conservative treatments fail, surgery is offered as an option to release the A1 pulley. Although high success and satisfaction rates have been reported, complications such as infection, digital artery, or nerve injury sometimes occur [9]. A previous study used a large percutaneous trigger thumb release in patients, but insufficient A1 pulley release occurred in severe cases, which required multiple releases [10].

Percutaneous release using a fine tenotome to treat trigger finger has been widely accepted among patients [7]; however, when higher triggering or nodules are present, more suitable instruments are needed for resolution of the symptoms [11]. Hence, the percutaneous release method should be considered. In this study, we present a modified percutaneous release technique using a specially designed needle to treat trigger thumb in 11 patients at a single center.

Material and Methods

NEEDLE AND PROCEDURE:

We treated trigger thumb using a specially designed needle (small needle, Beijing Huaxiatex Co. Ltd., Beijing, China), 0.8 mm in diameter and 100 mm in length (Figure 1). The needle is straight and stiff. The tip is planus to facilitate insertion into the skin. The width of the blade is 0.8 mm, and it can be used to safely release the A1 pulley with less damage.

For the procedure, the patients lay on a table in supine position, and the affected thumb was cleaned and placed on the table with the palm facing upward. The affected thumb was numbed using 1% plain lidocaine injected at the metacarpophalangeal joint crease. The thumb was then held in a hyperextended position and the tip of the specially designed needle was inserted through the skin into the triggering point of the A1 pulley. The needle tip was confirmed to be on the underside of the pulley when a grinding sensation was heard and felt and the bevel of the needle was parallel to the flexor sheath. The triggering release was done longitudinally, with several lifting movements from distal to proximal in the direction of the A1 pulley. When no more grating sound was heard, the needle moved freely at the tip of needle, ensuring a complete release. A 2-mg/mL steroid injection was injected into the sheath before the needle was withdrawn. A soft dressing was applied after the procedure was complete, and oral nonsteroidal anti-inflammatory drugs (NSAIDs) were prescribed for 3 days for pain control. All patients were interviewed by telephone at 3 months after the operation.

CLINICAL EVALUATION:

Outcome measures were analyzed based on visual analog scale (VAS) pain scores, the occurrence of triggering, the status of Notta’s node, patient satisfaction with treatment outcome, and the grade of trigger according to Quinnell’s criteria. Pain-related functional status was evaluated using a 10-cm VAS, on which 0 indicated no pain and 10 indicated severe pain. All patients were also asked to rate their pain based on 3 functional situations: at rest, active flexion or active extension, and grasping an object (over 4 kg). The overall VAS score was summed, with a maximum of 30 points for each patient. Pain scores were recorded preoperatively and at 3 months postoperatively. The Quinnell grading system for trigger finger [12,13] was based on the following scores: 0, normal movement; 1, uneven movement; 2, actively correctable locking of the digit; 3, passively correctible locking; and 4, fixed deformity.

All patients were interviewed at 3 months after the operation to learn whether the treated thumb no longer clicked or locked in a position of flexion or extension, the status of Notta’s node, and the grade of trigger according to Quinnell’s criteria using a questionnaire. The patients were also asked to rate their level of satisfaction from 0 to 5 (0 being unsatisfied and 5 being extremely satisfied).

STATISTICAL ANALYSIS:

The resultant data were calculated using a SPSS version 13 statistical software program. The VAS scores (the difference between the baseline and last assessment) were analyzed using a pair-wise t test, with P<0.05 being regarded as significant.

Results

THE TECHNIQUE EFFECTIVELY TREATED TRIGGER THUMB:

The mean time of surgery for trigger thumb was 4.5 min (ranging 3–7 min), including the time for local anesthesia. Initially, the 11 patients experienced triggering of stage III or higher. Eight patients had stage I or II triggering shortly after surgery, and they felt no triggering sensation and had full range of motion of the thumb at the final follow-up at 3 months. The first 2 patients had residual triggering with a grade of stage III. The sixth patient experienced persistent pain at the site of release (right thumb) at 1 week after the operation in spite of successful release. However, the pain resolved after 6 days by taking oral NSAIDs. None of the patients experienced significant complications from the percutaneous release technique.

VAS SCORE ANALYSIS SHOWED GOOD PROGRESS AFTER TREATMENT:

The preoperative mean VAS was about 21.6 (16–23), 7.2 points at rest, 8.5 points at flexion or extension, and 9.3 points when grasping objects. After the patients underwent percutaneous trigger thumb release, the mean VAS score decreased to 3.8 points at the third week postoperatively. Relative to the preoperative scores, the VAS scores decreased significantly (P<0.05) by 3 months after treatment: 0.6 points at rest, 1 point at flexion or extension, and 2.3 points when grasping objects. The comparison of the pain-rated functional situation VAS scores between preoperative and 3 months postoperative revealed a significant decrease (P=0.000; Table 3, Figure 2).

PATIENTS WERE SATISFIED WITH NEEDLE TREATMENT OUTCOMES:

When all patients were interviewed by telephone at 3 months postoperatively, 3 patients were satisfied and 8 patients were extremely satisfied with the results of the percutaneous release technique and had no recurrent triggering or nodules. All patients returned to their normal daily activities by 3 months after surgery. None of the patients had any complications such as inflammation, edema, or digital nerve injury (Table 4).

Discussion

The treatment applied in this study used the planus tip of a specially designed needle that was 0.8 mm in diameter to avoid damage to the adjacent neurovascular bundles. None of the 11 patients had complications. In contrast to other described percutaneous interventions in which a needle or knife is inserted to release the A1 pulley, this percutaneous operation for trigger thumb could be completed in 4.5 min on average by an adept operator. In comparison with an open procedure, it took less time and cost less. The planus tip of the specially designed needle enabled the operators to target the A1 pulley accurately, and the lift and thrust-cut technique was a safer and more effective method to completely resolve the trigger. Because each lifting action does not move at the same point, to minimize excessive damage to tendons during the procedure, the procedure was concluded as soon as the triggering disappeared. We were able to avoid damage to the adjacent neurovascular bundles. In cadaveric studies, percutaneous release was reported to cause less damage to the flexor tendons with small longitudinal tears [14–16].

Many similar percutaneous release techniques have been reported because of highly satisfactory results and few adverse effects, but the exact mechanism is still elusive [17–26]. The treatment approach is well accepted by patients. Although some authors have not favored percutaneous release because it poses a risk of injuring the digital nerves, we considered that such risk is likely due to the shape of the needle tip being similar to a hook or knife [26–28]. Such a shape may cause excessive damage to the A1 pulley, particularly since the process of releasing the A1 pulley is not visible. A previous study using a large percutaneous trigger thumb release in patients reported that insufficient release was obtained in severe cases, requiring multiple releases [10].

All patients in our study expressed overall satisfaction with the procedure at 3 months postoperatively. They experienced less pain, suggesting that patients should limit use of the treated thumb for 1 month after the operation. We believe that the percutaneous release technique is a better choice when severe triggering cannot be managed by steroid injection. We would also recommend it for patients whose symptoms have been occurring for less than 6 months or are below grade III triggering. The value of technique can be suitable for a broader population, including diabetic patients. However, this study had some limitations. It had a short-term follow-up and did not determine if patients had a recurrence of symptoms after several years. In addition, there is a lack of randomized clinical trials to evaluate the efficacy of percutaneous release technique compared with other treatments.

Conclusions

We developed a percutaneous technique using a specially designed needle to release trigger thumb. The procedure was used to treat 11 patients with trigger thumb. The specially made needles (ie, planus tip) and a validated release position (ie, A1 pulley release) were used in the procedure. The treatment outcomes suggested that this percutaneous release technique using a specially designed needle is effective for managing trigger thumb.

References

1. Drijkoningen T, van Berckel M, Becker SJE, Night splinting for idiopathic trigger digits: Hand (N Y), 2018; 13(5); 558-62

2. Saldana MJ, Trigger digits: Diagnosis and treatment: J Am Acad Orthop Surg, 2001; 9(4); 246-52

3. Jiménez I, Garcés GL, Marcos-García A, Medina J, A randomized controlled trial of dorsal web space versus palmar midline injection of steroid in the treatment of trigger digits: J Hand Surg Eur Vol, 2020; 45(10); 1071-77

4. Ha KI, Park MJ, Ha CW, Percutaneous release of trigger digits: J Bone Joint Surg Br, 2001; 83(1); 75-77

5. Luan TR, Chang MC, Lin CF, Percutaneous A1 pulley release for trigger digits: Zhonghua Yi Xue Za Zhi (Taipei), 1999; 62(1); 33-39

6. Chang CJ, Chang SP, Kao LT, A meta-analysis of corticosteroid injection for trigger digits among patients with diabetes: Orthopedics, 2018; 41(1); e8-e14

7. Weiss ND, Richter MB, Percutaneous release of trigger digits: Am J Orthop (Belle Mead NJ), 2017; 46(4); E263-67

8. Tanaka T, Ogawa T, Yanai T, Disruption of flexor tendon after intrasheath triamcinolone acetonide injection for trigger digits: Two case reports: J Hand Surg Asian Pac Vol, 2017; 22(3); 380-83

9. Lin FY, Manrique OJ, Lin CL, Cheng HT, Incidence of trigger digits following carpal tunnel release: A nationwide, population-based retrospective cohort study: Medicine (Baltimore), 2017; 96(27); e7355

10. Joseph J, Ditmars D, Percutaneous trigger thumb release: special considerations: Plast Reconstr Surg Glob Open, 2018; 6(6); e1758

11. Zyluk A, Mosiejczuk H, Outcomes of the treatment of trigger digits by extracorporal shock wave therapy (ESWT): Handchir Mikrochir Plast Chir, 2020; 52(1); 25-28

12. Quinnell RC, Conservative management of trigger finger: Practitioner, 1980; 224(1340); 187-90

13. Langer D, Maeir A, Michailevich M, Luria S, Evaluating hand function in clients with trigger finger: Occup Ther Int, 2017; 2017; 9539206

14. Wang J, Zhao JG, Liang CC, Percutaneous release, open surgery, or corticosteroid injection, which is the best treatment method for trigger digits?: Clin Orthop Relat Res, 2013; 471(6); 1879-86

15. Wessel LE, Fufa DT, Boyer MI, Calfee RP, Epidemiology of carpal tunnel syndrome in patients with single versus multiple trigger digits: J Hand Surg Am, 2013; 38(1); 49-55

16. Zhao JG, Kan SL, Zhao L, Percutaneous first annular pulley release for trigger digits: A systematic review and meta-analysis of current evidence: J Hand Surg Am, 2014; 39(11); 2192-202

17. Kanchanathepsak T, Pichyangkul P, Suppaphol S, Efficacy comparison of hyaluronic acid and corticosteroid injection in treatment of trigger digits: A randomized controlled trial: J Hand Surg Asian Pac Vol, 2020; 25(1); 76-81

18. Chen G, Xu H, Yao Y, BMP signaling in the development and regeneration of cranium bones and maintenance of calvarial stem cells: Front Cell Dev Biol, 2020; 8; 135

19. Zhang X, Shi G, Sun X, Factors influencing the outcomes of artificial hip replacements: Cells Tissues Organs, 2018; 206(4–5); 254-62

20. Chen G, Yao Y, Xu G, Zhang X, Regional difference in microRNA regulation in the skull vault: Dev Dyn, 2019; 248(10); 1009-19

21. Wu T, Chen G, Tian F, Liu HX, Contribution of cranial neural crest cells to mouse skull development: Int J Dev Biol, 2017; 61(8–9); 495-503

22. Hu B, Wu T, Zhao Y, Physiological signatures of dual embryonic origins in mouse skull vault: Cell Physiol Biochem, 2017; 43(6); 2525-34

23. Chen G, Ishan M, Yang J, Specific and spatial labeling of P0-Cre versus Wnt1-Cre in cranial neural crest in early mouse embryos: Genesis, 2017; 55(6), doi: 10.1002/dvg.23034

24. Chen G, Yang F, Wu T: PLoS One, 2016; 11(4); e0153342

25. Chen GQ, Hu XF, Sugahara K: J Zhejiang Univ Sci B, 2007; 8(11); 839-44

26. Godey SK, Bhatti WA, Watson JS, Bayat A, A technique for accurate and safe injection of steroid in trigger digits using ultrasound guidance: Acta Orthop Belg, 2006; 72(5); 633-34

27. Ryzewicz M, Wolf JM, Trigger digits: principles, management, and complications: J Hand Surg Am, 2006; 31(1); 135-46

28. Flatt AE, Notta’s nodules and trigger digits: Proc (Bayl Univ Med Cent), 2007; 20(2); 143-45

In Press

18 Mar 2024 : Clinical Research  

Sexual Dysfunction in Women After Tibial Fracture: A Retrospective Comparative Study

Med Sci Monit In Press; DOI: 10.12659/MSM.944136  

0:00

21 Feb 2024 : Clinical Research  

Potential Value of HSP90α in Prognosis of Triple-Negative Breast Cancer

Med Sci Monit In Press; DOI: 10.12659/MSM.943049  

22 Feb 2024 : Review article  

Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943168  

23 Feb 2024 : Clinical Research  

A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943732  

Most Viewed Current Articles

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750