Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

03 January 2020 : Laboratory Research  

Evaluation of the Precision of Different Intraoral Scanner-Computer Aided Design (CAD) Software Combinations in Digital Dentistry

Çise Erozan1ABCDEFG, Oğuz Ozan1ADE*

DOI: 10.12659/MSM.918529

Med Sci Monit 2020; 26:e918529

Abstract

BACKGROUND: The aim of this study was to evaluate the precision of correlation between intraoral scanners and computer aided design (CAD) software programs used during scanning and designing phases of digital dentistry. In the present study, CAD software programs that accept data in Standard Tessellation Language (STL) and proprietary format have been evaluated and data loss has been examined in the scanned data.

MATERIAL AND METHODS: A single unit crown preparation was conducted for maxillary right first molar on a fully dentulous model. The prepared tooth was scanned with a high precision industrial scanner (ATOS Core 80) and the reference digital model was obtained. The dental model was further scanned 10 times using 3 different intraoral scanners (CEREC Omnicam AC, TRIOS 3 Color Pod, and Aadva IOS 100). The data obtained from the reference scanner and intraoral scanners were transferred to different CAD programs (CEREC inLab, TRIOS Design Studio, Exocad) and digital crowns were designed for each scanned data-CAD combination. After that, the data losses that occurred between these transfers were evaluated by superimposition technique in a special software (VR Mesh v7.5) (α=0.05).

RESULTS: Among the all combinations of scanner and software, Omnicam AC-InLab was determined to be the most precise combination through the full digital workflow since the Omnicam AC-Exocad combination showed the highest deviations.

CONCLUSIONS: Within the limitations of this in vitro study, it was determined that the combinations of scanners and associated CAD programs yielded more accurate results, and data loss was revealed when the scanned data converted from the proprietary format to the STL format.

Keywords: Analog-Digital Conversion, Computer-Aided Design, Dental Clinics, Ceramics, Crowns, Dental Prosthesis Design, Dentistry, Imaging, Three-Dimensional, Models, Dental, Software

Comments

Editorial

01 May 2022 : Editorial  

Editorial: Cardiovascular Complications at One Year After SARS-CoV-2 Infection are Independent of Underlying Cardiovascular Risk Factors or Severity of COVID-19

Dinah V. Parums
Science Editor, Medical Science Monitor, International Scientific Information, Inc., Melville, NY, USA

DOI: 10.12659/MSM.937048

Med Sci Monit 2022; 28:e937048

SARS-CoV-2/COVID-19

24 May 2022 : Clinical Research  

Screening for SARS-CoV-2 Infection in Students at the Medical University of Warsaw, Poland Between November...

Med Sci Monit In Press; DOI: 10.12659/MSM.936962  

04 May 2022 : Clinical Research  

Effects of Wearing Face Masks on Exercise Capacity and Ventilatory Anaerobic Threshold in Healthy Subjects ...

Med Sci Monit In Press; DOI: 10.12659/MSM.936069  

27 May 2022 : Clinical Research  

Factors Associated with Falls During Hospitalization for Coronavirus Disease 2019 (COVID-19)

Med Sci Monit 2022; 28:e936547

In Press

27 May 2022 : Clinical Research  

Prognostic Significance of Preoperative Integrated Liver Inflammatory Score in Patients with Hepatocellular...

Med Sci Monit In Press; DOI: 10.12659/MSM.937005  

25 May 2022 : Review article  

Narrative Review of the Mechanism of Hip Prosthesis Dislocation and Methods to Reduce the Risk of Dislocation

Med Sci Monit In Press; DOI: 10.12659/MSM.935665  

24 May 2022 : Clinical Research  

Remimazolam Tosilate Sedation with Adjuvant Sufentanil in Chinese Patients with Liver Cirrhosis Undergoing ...

Med Sci Monit In Press; DOI: 10.12659/MSM.936580  

24 May 2022 : Clinical Research  

Screening for SARS-CoV-2 Infection in Students at the Medical University of Warsaw, Poland Between November...

Med Sci Monit In Press; DOI: 10.12659/MSM.936962  

Most Viewed Current Articles

30 Dec 2021 : Clinical Research  

Retrospective Study of Outcomes and Hospitalization Rates of Patients in Italy with a Confirmed Diagnosis o...

DOI :10.12659/MSM.935379

Med Sci Monit 2021; 27:e935379

08 Mar 2022 : Review article  

A Review of the Potential Roles of Antioxidant and Anti-Inflammatory Pharmacological Approaches for the Man...

DOI :10.12659/MSM.936292

Med Sci Monit 2022; 28:e936292

01 Nov 2020 : Review article  

Long-Term Respiratory and Neurological Sequelae of COVID-19

DOI :10.12659/MSM.928996

Med Sci Monit 2020; 26:e928996

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750