Abstract

BACKGROUND: The increase in the amount of extended spectrum beta-lactamases (ESBL)-producing gram-negative bacteria is seriously threatening human health in recent years. Therefore, it is necessary to develop a rapid and reliable method for identification of ESBLs. The purpose of this study was to establish a novel method to discriminate between ESBL-producing and non- ESBL-producing bacteria by using the matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) technique.

MATERIAL AND METHODS: We detected hydrolyzed production of cefotaxime after incubation with 69 gram-negative bacteria by using MALDI-TOF-MS. Then we established genetic algorithm (GA), supervised neural networks (SNN), and quick classifier (QC) models using several peaks to identify ESBL-producing strains. To confirm the clinical applicability of the models established, a blinded validation test was performed in 34 clinical isolated strains.

RESULTS: Using ClinPro Tools software, we identified 4 peaks (456 Da, 396 Da, 370 Da, and 371 Da) in mass spectra of cefotaxime solution that have high enough specificity to discriminate ESBL-producing from non- ESBL-producing strains. Recognition capability of models established were 97.5% (GA), 92.5% (SNN), and 92.5% (QC), and cross validation rates were 90.15% (GA), 97.62 (SNN), and 97.62% (QC). The accuracy rates of the blinded validation test were 82.4% (GA), 88.2% (SNN), and 82.4% (QC).

CONCLUSIONS: Our results demonstrate that identification of ESBLs strains by MALDI-TOF-MS has potential clinical value and could be widely used in the future as a routine test in clinical microbiology laboratories.

Keywords: Bacteria - isolation & purification, Algorithms, Cefotaxime - chemistry, Electrophoresis, Gel, Two-Dimensional, Models, Biological, Molecular Weight, ROC Curve, Reproducibility of Results, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization - methods, beta-Lactamases - biosynthesis

Add Comment 0 Comments

Most Viewed Current Articles

15 Jun 2022 : Clinical Research  

Evaluation of Apical Leakage After Root Canal Obturation with Glass Ionomer, Resin, and Zinc Oxide Eugenol ...

DOI :10.12659/MSMBR.936675

Med Sci Monit Basic Res 2022; 28:e936675

07 Jul 2022 : Laboratory Research  

Cytotoxicity, Apoptosis, Migration Inhibition, and Autophagy-Induced by Crude Ricin from Ricinus communis S...

DOI :10.12659/MSMBR.936683

Med Sci Monit Basic Res 2022; 28:e936683

01 Jun 2022 : Laboratory Research  

Comparison of Sealing Abilities Among Zinc Oxide Eugenol Root-Canal Filling Cement, Antibacterial Biocerami...

DOI :10.12659/MSMBR.936319

Med Sci Monit Basic Res 2022; 28:e936319

08 Dec 2022 : Original article  

Use of Estimated Glomerular Filtration Rate and Urine Albumin-to-Creatinine Ratio Based on KDIGO 2012 Guide...

DOI :10.12659/MSMBR.938176

Med Sci Monit Basic Res 2022; 28:e938176

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor Basic Research eISSN: 2325-4416
Medical Science Monitor Basic Research eISSN: 2325-4416