15 May 2014 : Original article
Anatomical study of suboccipital vertebral arteries and surrounding bony structures using virtual reality technology
Wenbo HaEF, DeLin YangBD, Shixin GuAG, Qi-Wu XuDE, Xiaoming CheBF, Jin-Song WuDF, Wensheng LiAGDOI: 10.12659/MSM.890840
Med Sci Monit 2014; 20:802-806
Abstract
BACKGROUND: This work aimed to evaluate the efficacy of virtual reality (VR) technology in neurosurgical anatomy through a comparison of the virtual 3D microanatomy of the suboccipital vertebral arteries and their bony structures as part of the resection of tumors in the craniovertebral junction (CVJ) of 20 patients compared to the actual microanatomy of the vertebral arteries of 15 cadaveric headsets.
MATERIAL AND METHODS: The study was conducted with 2 groups of data: a VR group composed of 20 clinical cases and a physical body group (PB group) composed of 15 cadaveric headsets. In the VR group, the dissection and measurements of the vertebral arteries were simulated on a Dextroscope. In the PB group, the vertebral arteries in the cadaver heads were examined under a microscope and anatomical measurements of VA and bony structures were performed. The length and course of the vertebral arteries and its surrounding bony structures in each group were compared.
RESULTS: The distances from the inferior part of the transverse process foramen (TPF) of C1 to the inferior part of TPF of C2 were 17.68±2.86 mm and 18.4±1.82 mm in the PB and VR groups, respectively. The distances between the middle point of the posterior arch of the atlas and the medial intersection of VA on the groove were 17.35±2.23 mm in the PB group and 18.13±2.58 mm in the VR group. The distances between the middle line and the entrance of VA to the lower rim of TPF of Atlas were 28.64±2.67 mm in PB group and 29.23±2.89 mm in VR group. The diameters of the vertebral artery (VA) at the end of the groove and foramen of C2 transverse process were 4.02±046 mm and 4.25±0.51 mm, respectively, in the PB group and 3.54±0.44 mm and 4.47±0.62 mm, respectively, in VR group. The distances between the VA lumen center and midline of the foramen magnum at the level of dural penetration was 10.4±1.13 mm in the PB group and 11.5±1.34 mm in the VR group (P>0.05).
CONCLUSIONS: VR technology can accurately simulate the anatomical features of the suboccipital vertebral arteries and their bony structures, which facilitates the planning of individual surgeries in the CVJ.
Keywords: Virtual Reality Exposure Therapy, Neurosurgical Procedures - methods, Occipital Lobe - blood supply, Spine - anatomy & histology, User-Computer Interface, Vertebral Artery - anatomy & histology
Editorial
01 April 2024 : Editorial
Editorial: Forty Years of Waiting for Prevention and Cure of HIV Infection – Ongoing Challenges and Hopes for Vaccine Development and Overcoming Antiretroviral Drug ResistanceDOI: 10.12659/MSM.944600
Med Sci Monit 2024; 30:e944600
In Press
21 Mar 2024 : Meta-Analysis
Economic Evaluation of COVID-19 Screening Tests and Surveillance Strategies in Low-Income, Middle-Income, a...Med Sci Monit In Press; DOI: 10.12659/MSM.943863
10 Apr 2024 : Clinical Research
Predicting Acute Cardiovascular Complications in COVID-19: Insights from a Specialized Cardiac Referral Dep...Med Sci Monit In Press; DOI: 10.12659/MSM.942612
06 Mar 2024 : Clinical Research
Enhanced Surgical Outcomes of Popliteal Cyst Excision: A Retrospective Study Comparing Arthroscopic Debride...Med Sci Monit In Press; DOI: 10.12659/MSM.941102
06 Mar 2024 : Clinical Research
Prevalence and Variation of Medical Comorbidities in Oral Surgery Patients: A Retrospective Study at Jazan ...Med Sci Monit In Press; DOI: 10.12659/MSM.943884
Most Viewed Current Articles
17 Jan 2024 : Review article
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
14 Dec 2022 : Clinical Research
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
01 Jan 2022 : Editorial
Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...DOI :10.12659/MSM.935952
Med Sci Monit 2022; 28:e935952