Detection of minor myocardial injury after successful percutaneous transluminal coronary angioplasty with or without stenting

Salam M. Saadeddin, Moh's A. Habbab, Samia H. Sobki, Gordon A. Ferns

Med Sci Monit 2000; 6(4): CR708-712 :: ID: 508179

Abstract

Cardiac troponins are sensitive and specific markers for the detection of minor myocardial injury. However, they have been rarely used to monitor myocardial injury after coronary stenting. The purpose of the study was to measure cardiac troponin I (cTnI) and cardiac troponin T (cTnT) levels after apparently successful percutaneous transluminal coronary angioplasty (PTCA) with or without coronary stenting and to compare their results with serum creatine kinase (CK) and its isoform, creatine kinase-MB (CKMB). CTnI and cTnT levels were compared with those of CK or CKMB in 50 consecutive patients with stable angina undergoing visually successful PTCA with stenting (n = 35) or without stenting (n = 15). Cardiac TnI, cTnT, CK and CKMB levels were measured before and 6, 24, and 48 hours after the procedures was performed. None of the patients had abnormal cTnI or cTnT levels, CK activity, or CKMB levels before the procedures. Moreover, no patient showed electrocardiographic evidence of myocardial infarction. 13 patients (26%) had abnormal peak values of one or more markers at 24 hours after coronary intervention. Troponin I was elevated in 10/35 patients after coronary stenting (29%) and in 2/15 patients after PTCA (13%) (P = 0.327). Troponin T was elevated in 6 patients (17%) and CKMB activity was elevated in 3 patients (9%) of the coronary stenting group. CTnI was more significant than CKMB (P = 0.023) in detecting minor myocardial injury. When compared with cTnI and CKMB, cTnT did not reach significance (P = 0.129 and 0.489, respectively). 5 out of the 13 patients with abnormal markers (38%) developed side branch occlusion after stenting. In conclusion, cTnI was a very sensitive marker in detecting minor myocardial injury after coronary angioplasty with or without stenting. The frequency of increased serum levels of cardiac troponins was higher in patients undergoing stent implantation than in those treated with angioplasty alone but did not reach significance. Side branch occlusion may have accounted for some, but not all, periprocedural minor myocardial injury in the stent group.
key words: myocardial injury, cardiac troponins, percutaneous transluminal coronary angioplasty, coronary stenting

Keywords: percutaneous transluminal coronary angioplasty, Cardiac troponins, myocardial injury, Coronary stenting

Add Comment 0 Comments

Editorial

01 April 2024 : Editorial  

Editorial: Forty Years of Waiting for Prevention and Cure of HIV Infection – Ongoing Challenges and Hopes for Vaccine Development and Overcoming Antiretroviral Drug Resistance

Dinah V. Parums

DOI: 10.12659/MSM.944600

Med Sci Monit 2024; 30:e944600

0:00

In Press

05 Mar 2024 : Clinical Research  

Muscular Function Recovery from General Anesthesia in 132 Patients Undergoing Surgery with Acceleromyograph...

Med Sci Monit In Press; DOI: 10.12659/MSM.942780  

05 Mar 2024 : Clinical Research  

Effects of Thermal Insulation on Recovery and Comfort of Patients Undergoing Holmium Laser Lithotripsy

Med Sci Monit In Press; DOI: 10.12659/MSM.942836  

05 Mar 2024 : Clinical Research  

Role of Critical Shoulder Angle in Degenerative Type Rotator Cuff Tears: A Turkish Cohort Study

Med Sci Monit In Press; DOI: 10.12659/MSM.943703  

06 Mar 2024 : Clinical Research  

Comparison of Outcomes between Single-Level and Double-Level Corpectomy in Thoracolumbar Reconstruction: A ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943797  

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750