Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

28 December 2016 : Clinical Research  

Effect of Refractive Correction Error on Retinal Nerve Fiber Layer Thickness: A Spectralis Optical Coherence Tomography Study

Xiaoli Ma1ACDE, Yutong Chen1BCG, Xianjie Liu1BCG, Hong Ning1DF*

DOI: 10.12659/MSM.898564

Med Sci Monit 2016; 22:5181-5189

Abstract

BACKGROUND: Identifying and assessing retinal nerve fiber layer defects are important for diagnosing and managing glaucoma. We aimed to investigate the effect of refractive correction error on retinal nerve fiber layer (RNFL) thickness measured with Spectralis spectral-domain optical coherence tomography (SD-OCT).

MATERIAL AND METHODS: We included 68 participants: 32 healthy (normal) and 36 glaucoma patients. RNFL thickness was measured using Spectralis SD-OCT circular scan. Measurements were made with a refractive correction of the spherical equivalent (SE), the SE+2.00D and the SE–2.00D.

RESULTS: Average RNFL thickness was significantly higher in the normal group (105.88±10.47 μm) than in the glaucoma group (67.67±17.27 μm, P<0.001). In the normal group, +2.00D of refractive correction error significantly affected measurements of average (P<0.001) and inferior quadrant (P=0.037) RNFL thickness. In the glaucoma group, +2.00D of refractive correction error significantly increased average (P<0.001) and individual quadrant (superior: P=0.016; temporal: P=0.004; inferior: P=0.008; nasal: P=0.003) RNFL measurements compared with those made with the proper refractive correction. However, –2.00D of refractive correction error did not significantly affect RNFL thickness measurements in either group.

CONCLUSIONS: Positive defocus error significantly affects RNFL thickness measurements made by the Spectralis SD-OCT. Negative defocus error did not affect RNFL measurement examined. Careful correction of refractive error is necessary to obtain accurate baseline and follow-up RNFL thickness measurements in healthy and glaucomatous eyes.

Keywords: Glaucoma - pathology, Demography, Nerve Fibers - pathology, Refractive Errors - diagnosis, Retina - pathology, Tomography, Optical Coherence - methods

Add Comment 0 Comments

Editorial

01 March 2024 : Editorial  

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and Transfusion-Dependent β-Thalassemia

Dinah V. Parums

DOI: 10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

In Press

21 Feb 2024 : Clinical Research  

Potential Value of HSP90α in Prognosis of Triple-Negative Breast Cancer

Med Sci Monit In Press; DOI: 10.12659/MSM.943049  

22 Feb 2024 : Review article  

Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943168  

23 Feb 2024 : Clinical Research  

A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943732  

26 Feb 2024 : Clinical Research  

Predictive Value of Combined HbA1c and Neutrophil-to-Lymphocyte Ratio for Diabetic Peripheral Neuropathy in...

Med Sci Monit In Press; DOI: 10.12659/MSM.942509  

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750