20 September 2015 : Clinical Research  

NeuroGam Software Analysis in Epilepsy Diagnosis Using 99mTc-ECD Brain Perfusion SPECT Imaging

Peng FuAB, Fang ZhangBC, Jianqing GaoCD, Jianmin JingBC, Liping PanBD, Dongxue LiE, Lingge WeiABCDEFG

DOI: 10.12659/MSM.894566

Med Sci Monit 2015; 21:2801-2808

Abstract

BACKGROUND: The aim of this study was to explore the value of NeuroGam software in diagnosis of epilepsy by 99Tcm-ethyl cysteinate dimer (ECD) brain imaging.

MATERIAL AND METHODS: NeuroGam was used to analyze 52 cases of clinically proven epilepsy by 99Tcm-ECD brain imaging. The results were compared with EEG and MRI, and the positive rates and localization to epileptic foci were analyzed.

RESULTS: NeuroGam analysis showed that 42 of 52 epilepsy cases were abnormal. 99Tcm-ECD brain imaging revealed a positive rate of 80.8% (42/52), with 36 out of 42 patients (85.7%) clearly showing an abnormal area. Both were higher than that of brain perfusion SPECT, with a consistency of 64.5% (34/52) using these 2 methods. Decreased regional cerebral blood flow (rCBF) was observed in frontal (18), temporal (20), and parietal lobes (2). Decreased rCBF was seen in frontal and temporal lobes in 4 out of 36 patients, and in temporal and parietal lobes of 2 out of 36 patients. NeuroGam further showed that the abnormal area was located in a different functional area of the brain. EEG abnormalities were detected in 29 out of 52 patients (55.8%) with 16 cases (55.2%) clearly showing an abnormal area. MRI abnormalities were detected in 17 out of 43 cases (39.5%), including 9 cases (52.9%) clearly showing an abnormal area. The consistency of NeuroGam software analysis, and EEG and MRI were 48.1% (25/52) and 34.9% (15/43), respectively.

CONCLUSIONS: NeuroGam software analysis offers a higher sensitivity in detecting epilepsy than EEG or MRI. It is a powerful tool in 99Tcm-ECD brain imaging.

Keywords: Brain - radionuclide imaging, Adolescent, Cysteine - analysis, Electroencephalography - methods, Epilepsy - radionuclide imaging, Image Interpretation, Computer-Assisted - methods, Magnetic Resonance Angiography - methods, Neuroimaging - methods, Organotechnetium Compounds - analysis, Software, Tomography, Emission-Computed, Single-Photon - methods, young adult

Add Comment 0 Comments

Editorial

01 March 2024 : Editorial  

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and Transfusion-Dependent β-Thalassemia

Dinah V. Parums

DOI: 10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

In Press

18 Mar 2024 : Clinical Research  

Sexual Dysfunction in Women After Tibial Fracture: A Retrospective Comparative Study

Med Sci Monit In Press; DOI: 10.12659/MSM.944136  

0:00

21 Feb 2024 : Clinical Research  

Potential Value of HSP90α in Prognosis of Triple-Negative Breast Cancer

Med Sci Monit In Press; DOI: 10.12659/MSM.943049  

22 Feb 2024 : Review article  

Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943168  

23 Feb 2024 : Clinical Research  

A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943732  

Most Viewed Current Articles

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750